Product Category

Search

LED 120V Indicator Light for Control Panels 2PIN Indicator Lamp FILN

Product Specifications
• Model: FL1P-10QW-2
• Color: Red, green, yellow, blue, and white
• Shape: Round plastic head
• Material: Lightweight plastic construction
• Finish Type: Plastic finish
• Light Source Type: LED
• Rated Voltage: Customizable from 3V to 480V AC/DC
• Rated Current: Customizable
• Mounting Type: Snap-in panel mounting
• Terminal / Wiring: 2-pin pre-wired connection with 150mm cable
• Protection Rating: CE, VDE, RoHS, ISO9001 Certified
• Product Size: 10 mm (0.39 inch)
• Other Key Specifications: Supplied by FILN for equipment manufacturers and control-panel builders
• Download PDF: 10mm 220v coffee machine plastic indicator light lamp-FL1P-10QW-2
• Email: inquiry@cnylin.com.cn

About this item
• Main Advantage: The FL1P-10QW-2 10mm plastic indicator light provides clear, reliable visual operating-status feedback for industrial equipment panels and control cabinets.
• Durability & Reliability: Constructed with a lightweight plastic housing offering a practical alternative to metal lamps, backed by CE, VDE, RoHS, and ISO9001 certifications.
• Installation & Compatibility: Engineered for quick snap-in panel mounting in a 10 mm (0.39 inch) cutout, featuring a 2-pin pre-wired connection with a 150mm cable.
• Applications: Designed for equipment manufacturers, control-panel builders, electrical wholesalers, and industrial purchasing teams requiring dependable status signaling.
• OEM & ODM: Factory support includes customizable voltage ranges from 3V to 480V AC/DC, multiple LED color options, and comprehensive configuration support.

10mm 220v coffee machine plastic indicator light lamp

Product Summary

FILN supplies this 10mm plastic 120V indicator light for equipment manufacturers, control-panel builders, electrical wholesalers, and industrial purchasing teams. It features a round plastic head, a 2-pin pre-wired connection, a 150mm cable, and snap-in panel mounting. Red, green, yellow, blue, and white LED colors are available. The voltage range is customizable from 3V to 480V, with the required operating voltage and AC/DC configuration confirmed before ordering. The lightweight plastic construction offers a practical alternative to metal indicator lamps in suitable equipment panels. Buyers can request samples, quotations, technical documents, and configuration support directly from FILN.

Ordering note: 120V is a requested voltage configuration, not a claim that every voltage version is held in stock. Confirm voltage, AC/DC type, LED polarity, wire length, and panel cutout before production.

Key Takeaways

  • Designed for a nominal 10mm panel mounting hole.
  • Round plastic indicator head for equipment-panel status indication.
  • 2-pin pre-wired connection with a stated 150mm lead length.
  • Custom voltage range from 3V to 480V, subject to configuration confirmation.
  • 120V configuration can be specified for compatible control-panel applications.
  • Five LED color choices: red, green, yellow, blue, and white.
  • Snap-in mounting uses two retaining ears on the indicator housing.
  • LED polarity depends on the selected configuration; polarized and non-polarity options may be available.
  • Lightweight plastic construction offers a cost-conscious alternative to metal indicator lights.
  • Suitable for a wide range of equipment panels when the electrical and environmental requirements are matched.
  • FILN can support buyers with sample requests, quotations, and configuration discussions.

What Is a Plastic Indicator Light?

Definition and Function

A plastic indicator light is a compact visual signal device installed in an equipment panel, control enclosure, or appliance housing. It uses an LED light source to communicate an operating condition, power status, warning, or process state. A 120V indicator light is commonly specified when the panel circuit is designed around a compatible 120V supply. The correct voltage and AC/DC configuration must always match the electrical design.

Structure and Purpose

A typical plastic panel indicator consists of a visible lens or head, a housing, an LED light source, a current-limiting component, and an electrical connection. This model uses a round head, two wire leads, and a snap-in retaining structure. Its purpose is to give operators a clear visual signal without requiring a large display or additional control interface.

Plastic and Metal Indicator Light Families

Panel indicators are commonly available in plastic and metal housing families. Plastic versions are often selected when low weight, insulation characteristics, convenient snap-in mounting, and cost control are priorities. Metal versions may be preferred where buyers need a different appearance, stronger mechanical housing, or a specific industrial design. Metal indicator products may also offer flat, raised, or recessed head styles.

Common Sizes and Connection Options

Plastic indicator lights are commonly offered in mounting sizes such as 6mm, 8mm, 10mm, 12mm, 16mm, and 22mm. Depending on the product family, connection choices may include pin terminals, pre-wired leads, and screw terminals. This page focuses on the 10mm pre-wired configuration rather than treating every connection style as part of this individual model.

Operating Principle and Industrial Value

When the specified supply is applied to a correctly configured indicator, the LED emits light through the colored head. The selected LED color communicates a status to an operator. A suitable resistor or other current-limiting design is used within the electrical circuit. For procurement, the important checks are the supply voltage, AC/DC type, current requirements, polarity, mounting dimensions, cable arrangement, and intended operating environment.

Typical Applications

A 120V indicator light can be specified for compatible control panels, electrical equipment, laboratory instruments, distribution cabinets, appliances, and other machinery. The exact suitability depends on the selected electrical configuration and the environmental requirements of the finished equipment.

FILN plastic panel indicator light product family with compact round indicator heads

Request a Sample Buy This Indicator
Request Datasheet PDF Request 3D Model / CAD
Explore the Complete FILN Plastic Indicator Light Range

Browse additional panel indicator sizes, colors, wiring arrangements, and plastic indicator configurations for different equipment designs.

View All Plastic Indicator Lights

Product Overview

The FILN 10mm pre-wired plastic indicator is designed for panel builders who prefer a compact lamp with an attached two-wire connection. The 150mm leads reduce the need to prepare a separate short wiring harness for every indicator position. The snap-in housing is inserted from the front of the panel, where its two retaining ears hold the body in place.

The LED color can be selected according to the equipment’s signal logic. The available choices are red, green, yellow, blue, and white. Depending on the ordered LED configuration, the light source may be polarized or non-polarity. Buyers should identify the required version on the purchase order rather than assume that every configuration uses the same connection polarity.

For a 120V indicator light order, specify the nominal supply, AC or DC operation, LED color, wire length, and polarity requirement. The product voltage range is customizable from 3V to 480V; the exact electrical design must be confirmed for the selected voltage.

Quick Specifications

Attribute Specification
Product name Plastic LED panel indicator light
Model FL1P-10QW-2
Mounting hole size 10mm (approximately 0.394 in; confirm drawing tolerance before panel machining)
Voltage range 3V–480V, customizable; 120V configuration can be requested
AC/DC type Confirm AC or DC requirement when ordering
LED colors Red, Green, Yellow, Blue, White
Connection 2-pin pre-wired leads
Lead length 150mm
Head style Round plastic head
Mounting method Snap-in mounting with two retaining ears
Polarity Polarized or non-polarity LED option; confirm selected configuration
Package contents 1 × plastic indicator light
Product marks / certifications stated for this offering CE, VDE, RoHS, CCC; confirm documentation for the ordered configuration. ISO9001 applies to the company quality management system.
Typical use Equipment panels, electrical cabinets, laboratory equipment, appliances, and machinery

The 10mm inch conversion is approximate. Confirm the product drawing, panel thickness, and fit dimensions before production machining.

Performance Parameters

Parameter Available information
Operating voltage 3V–480V, customizable; specify the required nominal voltage
120V configuration Available by voltage configuration request; confirm AC/DC type
LED current Not specified for this exact configuration
Rated power Not specified for this exact configuration
Insulation resistance Request the technical datasheet for the selected configuration
Dielectric strength Request the technical datasheet for the selected configuration
Ingress protection Not specified for this exact model; confirm the required IP rating
Rated operating life Not specified for this exact model

Do not select a 120V indicator solely by the nominal voltage label. The electrical design, circuit type, polarity, insulation requirements, and environmental rating must be confirmed for the ordered version.

Component Materials

Component Material / details
Housing Nylon PA66 series material reference; confirm exact bill of materials for this order
Base Nylon PA66 series material reference; confirm exact bill of materials for this order
Lens / head Plastic round head; exact material grade to be confirmed against the product drawing
Light source LED; polarized or non-polarity option depending on configuration
Current-limiting component Confirm circuit details for the selected voltage
Lead wire Two leads, 150mm stated length; wire material and gauge to be confirmed on the datasheet
Mounting hardware Two retaining ears integrated into the snap-in housing

Plastic housings are commonly selected for their low weight, electrical insulation characteristics, and suitability for compact panel assemblies. The final material specification should be checked against the approved drawing and bill of materials before a regulated or safety-critical application is released.

Environmental Performance

The product is described for use in a broad range of equipment, but the exact operating temperature, humidity limits, ingress protection, and vibration performance for this model have not been supplied in the current product specification. These values should not be assumed from appearance or mounting style.

Environmental item Specification status
Operating temperature Confirm with FILN for the selected configuration
Storage temperature Confirm with FILN
Relative humidity Confirm with FILN
Ingress protection Confirm the required IP rating; no washdown or immersion claim is made here
High-temperature resistance A product selling point; request test conditions and limits for engineering approval

LED Specification

The LED is available in five color choices. Electrical and optical values can vary with the selected LED, voltage, and circuit design. The values below identify the options confirmed for this product offering without assuming unprovided brightness, wavelength, or forward-voltage data.

LED color Typical signal use Optical data
Red Warning, fault, stop, or attention status Confirm selected LED datasheet
Green Normal operation, ready, or running status Confirm selected LED datasheet
Yellow Caution, standby, or transitional status Confirm selected LED datasheet
Blue Special function or auxiliary status Confirm selected LED datasheet
White Power indication or general illumination status Confirm selected LED datasheet

Color meanings are common industry conventions, not universal rules. Follow the equipment manufacturer’s control logic and applicable project standards.

Standard Test Conditions

No complete test-condition schedule or optical measurement report for this exact model has been included in the current product information. For a 120V indicator light used in a production control panel, purchasing and engineering teams should request the applicable electrical, insulation, dielectric, environmental, and optical test records before approving the component.

Test or document Buyer action
Rated voltage verification Confirm the requested voltage and AC/DC configuration
Polarity check Identify polarized or non-polarity LED version
Insulation and dielectric testing Request the applicable test method and report
Temperature testing Confirm operating limits and test conditions
Photometric data Request brightness, viewing angle, and wavelength data where required
Compliance documents Match certificates and declarations to the ordered configuration and destination market

Applications by Industry

A 120V indicator light is used in equipment where operators need a clear visual signal from the control panel. The round head and attached two-pin leads make this style relevant to compact panel layouts, provided the voltage, mounting, and environmental requirements are compatible.

Industrial Electrical Equipment

Use a panel indicator to show power availability, operating status, alarm conditions, or equipment readiness. Panel builders should match the lamp voltage to the control circuit and allow sufficient space behind the panel for the 150mm leads and wiring connections.

Laboratory and Test Equipment

Laboratory instruments and test benches often use compact signal lamps to show power, test activity, standby, or fault states. The small mounting format can help organize multiple indicators on a limited front panel.

Distribution Cabinets and Control Panels

A 120V indicator light may be selected for a compatible control supply to show whether a circuit or equipment section is energized. The wiring diagram should define the signal function and ensure that the indicator is connected to the correct circuit.

New Energy Equipment

Energy-related equipment may use colored panel indicators to distinguish operating states, charging status, alarms, or auxiliary functions. The required voltage, temperature range, ingress protection, and vibration resistance should be confirmed against the final installation environment.

Yacht and Marine Equipment

Marine control panels can use indicator lights for switch status, auxiliary systems, and equipment feedback. Buyers should verify the environmental and corrosion requirements before specifying this plastic panel indicator for a marine installation. Do not assume that a standard panel indicator is suitable for direct exposure to water or salt spray.

Household Appliances and Automotive Modification

Appliance control panels and vehicle accessory panels may use compact indicators for power and operating status. For automotive modification, confirm the vehicle supply, transient protection requirements, panel material, and installation conditions before choosing a voltage configuration.

Plastic indicator lights used in equipment panels and industrial electrical applications

Application suitability depends on the actual product rating and the equipment environment. Request the detailed specification if the installation involves moisture, outdoor exposure, high vibration, or elevated temperature.

LED Indicator Color Meanings and Application Guide

Color selection should follow the control-system logic, equipment documentation, and the conventions used by the end customer. The five available colors provide flexibility for different panel layouts, but the meaning of a color can vary by industry, manufacturer, country, and application.

Color Common meaning Typical status Selection note
Red Warning or danger Fault, stop, emergency attention Use where the equipment logic assigns a high-priority warning
Green Normal condition Ready, running, or operating Confirm the green signal represents a safe or normal state in the system
Yellow Caution Standby, transition, or attention required Define the exact warning level in the equipment manual
Blue Special instruction or auxiliary state Special mode or operator action Use only when the control scheme defines the meaning
White General status or power indication Auxiliary indication or general function Confirm visibility against the panel background and ambient light

These are common usage patterns rather than universal definitions. Where a project standard or customer specification defines color meanings, that document takes priority. Single-color, dual-color, or multi-color arrangements should be confirmed separately; this page describes the five available single-color choices.

How to Install a Plastic Indicator Light

This model uses a snap-in mounting method. Its round head is visible on the front of the panel, while the housing and two retaining ears secure the indicator in the mounting opening behind the panel face.

Tools and Preparation

Prepare a suitable panel-hole tool, measuring equipment, and the product drawing. Disconnect the power supply before installation or wiring. Check the panel material, thickness, available rear clearance, and the 10mm mounting requirement before making the opening.

Installation Steps

  1. Measure and mark the intended indicator position on the equipment panel.
  2. Make a circular mounting hole that matches the specified 10mm installation size. Check the product drawing for tolerance and panel-thickness requirements.
  3. Remove burrs and debris from the opening so the indicator housing can seat correctly.
  4. Position the round indicator head above the panel opening and align the housing with the hole.
  5. Insert the indicator from the front or upper side of the panel into the circular opening.
  6. Push the body into place until the two retaining ears on the housing engage behind the panel and hold the indicator securely.
  7. Check that the head sits straight and that the housing does not rotate, tilt, or loosen.
  8. Route the two 150mm leads without pulling, pinching, or sharply bending the wires.
  9. Connect the leads according to the selected voltage, AC/DC type, and LED polarity configuration.
  10. Restore power only after the wiring has been inspected, then verify the indicator function.

Panel Fit and Installation Checks

The retaining ears must engage the panel securely. A hole that is too large may reduce retention, while an undersized opening can damage the housing during insertion. Do not force the indicator into an opening that does not match the drawing. Confirm the required panel thickness and any environmental sealing requirements with FILN before finalizing the panel design.

Common Installation Mistakes

  • Using a hole size without checking the drawing tolerance.
  • Installing the indicator into a panel that is too thick for the retaining ears.
  • Pulling the lead wires tightly against sharp panel edges.
  • Connecting a polarized LED without checking its positive and negative leads.
  • Applying power before checking the rated voltage and AC/DC type.
  • Assuming snap-in mounting automatically provides a waterproof seal.

Safety Precautions

Always isolate the circuit before installation and wiring. The 120V indicator light configuration must be handled by personnel qualified to work with the relevant electrical system. Use suitable insulation, connectors, and wiring practices for the application. Do not energize exposed conductors or leave unprotected joints inside the equipment.

Panel installation example showing a compact indicator light fitted into a mounting hole

How to Wire a Plastic Indicator Light

This model is supplied with two attached wire leads. The leads are connected to the equipment circuit after the indicator has been mounted. Before wiring, verify the rated voltage, AC/DC type, polarity option, and the circuit diagram. Never assume that a product configured for one voltage can be connected directly to another supply.

Wiring the Pre-Wired Version

  1. Disconnect the equipment power source.
  2. Identify the two indicator leads and check the product wiring information.
  3. For a polarized LED, identify positive and negative leads and connect them according to the wiring diagram.
  4. For a non-polarity LED configuration, connect the two leads according to the approved circuit diagram without requiring positive/negative matching at the LED.
  5. Use a suitable terminal, connector, or correctly completed soldered joint for the application.
  6. Insulate and secure all connections, then check for shorts, loose conductors, and damaged insulation.
  7. Restore power and verify the indicator under the specified operating conditions.

Polarized and Non-Polarity LED Options

Some LED configurations require the positive and negative connections to be matched. Other configurations use a non-polarity LED and can be connected without matching positive and negative at the LED itself. This is a configuration choice, not a universal feature of every version. State the required polarity option when requesting a quotation or sample.

Pin-Type and Wire-Lead Comparison

Plastic indicator product families may include both pin-type and pre-wired designs. The comparison below helps purchasing teams choose the connection style that fits their assembly process. It does not mean both versions are included in this model’s package.

Comparison 2-Pin Plug-In / Pin Type 2-Pin Pre-Wired / Wire Lead
Connection method Connects through exposed pin terminals and a matching connector or board arrangement Two attached leads connect to the equipment wiring
Main advantages Compact terminal arrangement; can suit standardized connectors and repeatable assembly Flexible routing; no separate short lead harness is needed at the indicator itself
Potential limitations Requires a compatible socket, connector, or board layout Requires wire routing, termination, and sufficient rear clearance
Assembly considerations Check pin spacing, connector fit, and mechanical support Check lead length, wire gauge, insulation, strain relief, and terminal type
Typical use cases Equipment with a prepared connector or PCB-based wiring arrangement Control cabinets, equipment panels, appliances, and installations needing flexible wire routing
This model Not this model’s stated connection 2-pin wire leads, 150mm stated length

Preventing Faint or Unwanted LED Glow

In some low-current circuits, leakage current, induced voltage, or electronic switching components may allow a small current to pass through an indicator when the main circuit is intended to be off. This can cause faint illumination. If this occurs, have a qualified engineer check the circuit design, switching device, and indicator compatibility. Do not add components or alter mains wiring without confirming the correct electrical design.

Always disconnect power before wiring. Follow the product drawing and applicable electrical safety requirements for the installation country.

Industry Knowledge Center

Why Panel Indicators Matter

A panel indicator provides immediate visual feedback without requiring an operator to open the enclosure or use a separate measurement instrument. It can help distinguish power status, machine readiness, warnings, and auxiliary functions. Clear labeling and consistent color assignment make the panel easier to understand during operation and maintenance.

Choosing a Voltage Configuration

The nominal voltage is one of the first details to confirm when sourcing an indicator. A 120V indicator light must be matched to the actual circuit and the product’s specified AC/DC type. A voltage range offered by a manufacturer does not mean that one individual unit automatically supports every voltage in that range. Each order should identify the required nominal voltage and configuration.

Understanding Product Certifications

Procurement teams may request CE, VDE, RoHS, CCC, or an ISO9001 certificate as part of supplier qualification. These documents do not all describe the same thing. Product declarations or approvals should be checked against the specific indicator configuration and destination market. ISO9001 relates to a company’s quality management system; it is not a product approval for an individual lamp.

Common Selection and Maintenance Errors

  • Ordering by voltage alone without confirming AC/DC type.
  • Assuming a polarized LED and a non-polarity LED have identical wiring requirements.
  • Choosing a panel hole based only on a nominal size without checking tolerance.
  • Ignoring the rear clearance needed for the attached wire leads.
  • Assuming a plastic housing automatically meets a particular IP or temperature rating.
  • Replacing an indicator with a different voltage or color without checking the control circuit.

Inspection and Troubleshooting

If an indicator does not illuminate, first isolate the supply and check the selected voltage, circuit continuity, wiring connections, and polarity requirement. If it glows faintly while switched off, investigate leakage or induced current in the control circuit. If the head is loose, inspect the panel opening and the retaining ears. Replace damaged parts only with a configuration that matches the original electrical and mechanical requirements.

How to Choose a Plastic Indicator Light for Procurement

1. Match the Electrical Supply

Start with the circuit voltage and whether the supply is AC or DC. If the project calls for a 120V indicator light, state 120V explicitly in the RFQ and identify the circuit type. Also confirm whether the selected LED requires polarity matching.

2. Confirm Mounting and Wiring

Check the 10mm mounting hole, panel thickness, rear clearance, snap-in retention, and lead length. The stated 150mm wires should reach the intended connection point without tension or unsafe extensions. If a longer lead or a connector is required, specify it before ordering.

3. Select the LED Color

Choose red, green, yellow, blue, or white according to the equipment’s control logic. If the customer has an existing color standard, include it in the purchasing specification to avoid inconsistent panel indications.

4. Compare Mounting Sizes

Nominal mounting hole Approximate inch conversion Typical panel use
6mm 0.236 in Very compact panels and small instruments
8mm 0.315 in Compact equipment indicators
10mm 0.394 in General equipment panels and appliances
12mm 0.472 in Small-to-medium control panels
16mm 0.630 in Larger panel indication layouts
22mm 0.866 in Standard-size industrial control interfaces

The inch values are approximate conversions only. Use the approved product drawing to determine the final panel cutout and tolerance.

5. Plastic or Metal Housing?

Consideration Plastic indicator Metal indicator
Weight Generally lighter Generally heavier
Electrical insulation Plastic housing is electrically insulating Metal housing requires appropriate insulation design
Mechanical housing Suitable for applications matched to the selected plastic grade and design May be preferred where a metal body or different mechanical feel is required
Cost and assembly Often cost-effective for lightweight, high-volume equipment panels Cost depends on metal, finish, and assembly structure
Possible metal materials Not applicable to this plastic housing May include plated brass, stainless steel, or zinc alloy depending on product family

This comparison describes general housing-family differences. It does not claim that this plastic model has the mechanical or environmental ratings of a metal indicator. For a metal alternative, view the FILN metal indicator light range or the 10mm metal indicator lights.

6. Match the Product to the Application Environment

Check temperature, humidity, dust, water exposure, vibration, impact, and cleaning conditions. A product should only be used where its documented ratings meet the equipment requirements. If the panel is exposed to water, outdoor weather, washdown, or corrosive conditions, request a suitable alternative and its supporting test documents.

7. Specification-to-Decision Framework

Specification Why it matters What to confirm
Voltage Determines compatibility with the supply circuit 120V or another nominal value; AC/DC type
Mounting hole Controls fit and retention on the panel 10mm cutout and tolerance from drawing
Connection Affects installation labor and wiring layout 2-pin pre-wired leads, 150mm length, connector needs
LED color Communicates equipment status Red, green, yellow, blue, or white
Polarity Affects wiring orientation for some LED versions Polarized or non-polarity version
Certification Supports market and project compliance review Document type, issuing body, validity, and exact product configuration

RFQ Checklist for Purchasing Teams

To receive a relevant quotation, include the following information in your request:

  • Product type and model: FL1P-10QW-2
  • Mounting hole size and panel thickness
  • Required voltage and AC/DC type
  • LED color
  • Round head requirement
  • Plastic material or approved material specification
  • Required IP or environmental rating
  • Wiring method: 2-pin pre-wired leads
  • Wire length: 150mm or requested alternative
  • Connector or terminal requirement
  • Polarized or non-polarity LED requirement
  • Certification and destination-market requirements
  • Order quantity and packaging requirements
  • OEM requirements, logo, or custom marking
  • Target market and application environment
  • Required delivery date for quotation planning

Providing these specifications helps FILN engineering and sales teams confirm product compatibility and quotation requirements more efficiently. Price and lead time depend on the confirmed configuration and order details.

Send an RFQ Request Technical Documents
Need a Different 10mm Indicator Configuration?

Compare additional plastic and metal options before finalizing your panel design.

Explore More 10mm Plastic Indicator Lights
Compare 10mm Metal Indicator Lights

FILN Manufacturing and Engineering Capabilities

FILN is the brand of Yueqing Yulin Electronic Co., Ltd, a manufacturer focused on indicator lights, switches, and related electronic components. The company works with equipment manufacturers, distributors, wholesalers, and industrial purchasing teams that need standard components or customized electrical parts.

Product Development and Engineering Communication

For indicator-light projects, engineering discussions can cover mounting dimensions, voltage configuration, LED color, polarity, cable length, wiring arrangements, and application requirements. Providing drawings, circuit information, and target-market requirements helps the team evaluate the requested configuration.

OEM and ODM Support

OEM and ODM discussions may include product configuration, customized wiring, application-specific requirements, and other agreed product details. The final scope depends on technical feasibility, order requirements, and confirmation by the FILN team.

Quality and Documentation Support

Business buyers can request available product specifications, drawings, and compliance documents for review. Company-level quality-system information should be distinguished from product-specific declarations and approvals. Any requested certificate should be checked against the exact model and electrical configuration.

Product Range

FILN’s product range includes plastic and metal indicator lights, push-button switches, rocker switches, toggle switches, and related customized electronic components. This range allows buyers to discuss multiple panel-control component requirements with one manufacturing supplier.

FILN company introduction and electronic component manufacturing overview

Visit the FILN company website to learn more about the manufacturer and its electronic component product range.

Factory Direct Supply

Yueqing Yulin Electronic Co., Ltd operates under the FILN brand and supplies electronic components to international customers. Its product range covers indicator lights, push-button switches, rocker switches, toggle switches, and related customized electrical components.

For industrial purchasing teams, working directly with a manufacturer can make it easier to discuss product drawings, electrical configurations, wiring requirements, samples, and repeat-order specifications. FILN can communicate with buyers about the required 120V indicator light configuration and other voltage options within the stated customizable range.

The company has experience supporting overseas customers and export orders. Buyers can contact the team to discuss product selection, documentation, sample evaluation, and OEM or ODM requirements. Order quantity, production schedule, and delivery arrangements should be confirmed in the quotation process rather than assumed from general product information.

FILN electronic components manufacturing workshop and production environment

Contact FILN for Plastic Indicator Light Purchasing

Send your voltage, color, mounting, lead length, quantity, and documentation requirements to the sales team for configuration review.

Contact FILN Sales Team

Browse all plastic indicator lights or compare the metal indicator light range.

Frequently Asked Questions

What is a 120V indicator light used for?

A 120V indicator light provides a visible signal on equipment designed with a compatible 120V circuit. It can show power status, operating conditions, warnings, or other defined equipment states. The correct AC/DC type and electrical configuration must be confirmed before installation. FILN offers this 10mm plastic panel indicator with a customizable voltage configuration.

What is the mounting hole size of this plastic indicator?

This model is designed for a nominal 10mm panel mounting hole, approximately 0.394 inches. The actual cutout tolerance and suitable panel thickness should be checked against the product drawing before machining. A correct opening helps the two retaining ears engage securely behind the panel.

Can I order this indicator for 120V AC?

A 120V configuration can be requested within the stated customizable voltage range of 3V to 480V. Specify whether the required supply is 120V AC or another circuit type when contacting FILN. Do not assume that an indicator configured for DC can be connected to an AC supply, or vice versa, without confirmation.

Does this model have a pre-wired connection?

Yes. The stated connection is a two-pin pre-wired lead arrangement with a cable length of 150mm. The two leads connect to the equipment wiring after the indicator is mounted. If your project requires a different lead length, connector, or terminal arrangement, include that requirement in your inquiry for confirmation.

What LED colors are available?

The available LED color choices are red, green, yellow, blue, and white. Select the color according to the equipment’s signal logic and customer requirements. If your panel uses a defined color convention, include the intended status for each color in the product specification or purchase order.

Is this LED indicator polarized?

The available configuration may use either a polarized LED or a non-polarity LED. A polarized version requires the positive and negative leads to be connected in the correct orientation. A non-polarity version does not require positive and negative matching at the LED. Confirm the selected option with FILN before ordering.

How is the 10mm plastic indicator installed?

Make a circular opening that matches the specified 10mm mounting size and drawing tolerance. Insert the indicator from the front of the panel, then push the housing into the opening until its two retaining ears engage behind the panel. Check that the head is straight and secure before connecting the two leads.

What is the difference between pin-type and pre-wired indicator lights?

A pin-type indicator uses exposed terminal pins and normally requires a compatible connector or board arrangement. A pre-wired indicator has attached leads that can be routed to the equipment wiring. Pin-type products can suit standardized connector layouts, while pre-wired versions offer more flexibility for panel wiring. This model is the pre-wired version.

Is this plastic indicator waterproof?

A specific IP rating has not been provided for this model in the current product information. Do not assume that snap-in mounting makes the indicator waterproof. If your equipment requires protection from water, dust, outdoor exposure, or washdown, state the required IP rating and ask FILN to confirm a suitable product with supporting documentation.

Can the wire length be customized?

The stated lead length for this product is 150mm. If your equipment layout requires a longer or shorter cable, provide the requested length and any connector or termination details in your inquiry. Customization should be confirmed by FILN before the purchase order is finalized.

What certifications are associated with this product offering?

The product information supplied for this offering lists CE, VDE, RoHS, and CCC. Ask FILN for the applicable documents and verify that they cover the exact voltage and product configuration being purchased. ISO9001 is a company quality management system certification, not an individual indicator-light product certification.

Can FILN provide samples before bulk purchasing?

Buyers can contact FILN to discuss sample availability and the required configuration. Include the voltage, AC/DC type, LED color, mounting size, polarity, and wire length so the sample can be matched to the intended equipment. Use the sample request link to contact the sales team.

Can I request a datasheet or 3D drawing?

Yes. Contact FILN to request available technical documents or a 3D model for design review. Include the model number, mounting dimensions, panel thickness, voltage, and wiring requirements. The engineering team can confirm which documents are available for the selected configuration.

Can this indicator be used in laboratory equipment?

It may be suitable for laboratory equipment panels when the selected voltage, installation dimensions, and environmental requirements match the equipment design. Review the actual operating conditions, including cleaning exposure, humidity, temperature, and any required ingress protection, before approving the component for the instrument.

Why choose a plastic indicator instead of a metal indicator?

Plastic indicators are often selected for their lighter weight, electrical insulation characteristics, and cost-effective construction. Metal indicators may be preferred when a metal housing, different appearance, or specific mechanical requirements are needed. The right choice depends on the panel design and the documented environmental and mechanical ratings of the product.

What should I include in a bulk purchasing inquiry?

Include the model, order quantity, voltage, AC/DC type, LED color, 10mm mounting hole, panel thickness, 150mm or customized lead length, polarity option, connector requirements, certification needs, destination market, and application environment. Complete information helps the sales and engineering teams assess compatibility and prepare a more relevant quotation.

Does FILN manufacture other 10mm indicator lights?

FILN offers a broader indicator-light range, including plastic and metal product families. Buyers can compare additional 10mm plastic configurations through the 10mm plastic indicator category or review the 10mm metal indicator range.

Can this indicator be used in automotive modification projects?

It may be considered for suitable accessory or interior panels when the electrical configuration and installation environment are compatible. Automotive circuits can involve voltage variation and electrical transients, so confirm the required supply range, protection design, and environmental conditions with the equipment engineer before use.

How do I buy this 10mm plastic indicator light?

You can review the product and submit an order inquiry through the FILN product page. Before purchasing, confirm the voltage, AC/DC type, LED color, polarity option, wire length, and required documentation. For bulk orders or custom requirements, contact FILN directly.

How can I contact FILN for a customized indicator light?

Send your technical requirements to inquiry@cnylin.com.cn. Include the target voltage, color, mounting dimensions, lead length, polarity, quantity, and application. FILN can review the request and discuss the available configuration and documentation.

Inquiry Now