Product Summary
The FILN 10mm high-head plastic led bulb indicator (Model: FL1P-10NJ-3) is a lightweight, cost-effective signaling component engineered for control panels, electrical equipment, test benches, and commercial appliances. Constructed with a heat-resistant Nylon PA66 enclosure, base, and round high-head lens, this led bulb indicator provides bright, clear visual status indication across standard panel cutouts of 10mm (Ø0.394 in). Designed with 2PIN plug terminals and a nut-locking mounting structure, it supports configuration-dependent voltages including 2V, 3V, 6V, 12V, 24V, 48V, 110V, 220V, and 380V AC/DC at ≤ 20 mA. Rated at IP50 for enclosed indoor panel environments and compliant with RoHS standards, this led bulb indicator includes non-polarity LED options and full OEM/ODM customization support from Yueqing Yulin Electronic Co., Ltd.
Key Takeaways
- Standard 10mm Mounting Cutout: Fits a 10mm (Ø0.394 in) circular panel hole and fastens securely using the included plastic locking nut.
- High-Head Round Lens Profile: Protruding round dome improves side-angle visibility on crowded control cabinets and machinery panels.
- Nylon PA66 Housing Construction: Provides reliable electrical insulation, thermal stability from −15°C to +80°C, and lower weight than metal housings.
- 2PIN Plug Terminal Interface: Enables fast plug-in harness connection and straightforward maintenance replacement without desoldering.
- Non-Polarity 5mm LED Source: Simplifies DC circuit installation by eliminating positive and negative terminal polarity restrictions.
- Configuration-Dependent Voltage Options: Available in 2V, 3V, 6V, 12V, 24V, 48V, 110V, 220V, and 380V AC/DC configurations, plus custom voltage builds.
- IP50 Dust Protection Rating: Suitable for enclosed panels and indoor electrical equipment, though not rated for outdoor washdown or immersion.
- 60,000-Hour Rated Working Life: Engineered for long operational service life under specified electrical and environmental conditions.
- Verified Product Compliance: This plastic led bulb indicator offering is RoHS compliant; confirm additional regional marks with FILN before ordering.
- Pre-Order Verification Checklist: Buyers should confirm mounting hole size, rated voltage, AC/DC type, LED color, and terminal style prior to procurement.
What Is a Plastic Indicator Light?
A plastic led bulb indicator is a panel-mounted visual signaling device housed in an engineered polymer body that illuminates to communicate equipment power, operating status, or fault conditions. Within industrial signaling hardware, pilot lamps fall into two primary structural categories: metal indicator lights and plastic indicator lights. While metal variants are often built with flat, convex, or concave heads for heavy mechanical impact, plastic indicator lights prioritize electrical insulation, lightweight assembly, corrosion resistance, and versatile sizing across 6mm, 8mm, 10mm, 12mm, 16mm, and 22mm panel apertures. Internally, a current-limiting resistor regulates supply voltage to drive a 5mm LED emitter in Red, Green, Yellow, Blue, or White. Across the broader plastic product family, manufacturers offer three termination styles—pin-type terminals, pre-wired wire leads, and screw terminals—giving panel builders flexibility for control cabinets, instruments, and appliances.

| Request a Sample | Buy This Indicator |
| Request Datasheet PDF | Request 3D Model / CAD |
Open Full Plastic Indicator Category
Product Overview
The FILN FL1P-10NJ-3 led bulb indicator combines a threaded Nylon PA66 barrel with a high-head round lens and a matching plastic locking nut for secure panel mounting. Once inserted through a 10mm panel cutout, the nut tightens along the rear threads to hold the assembly firmly without rotation, tilting, or loosening under routine equipment operation. Inside the insulated PA66 body, a carbon film resistor pairs with a 5mm non-polarity LED lamp bead so technicians can connect 2PIN plug terminals without worrying about positive or negative wire orientation. This structural layout delivers high brightness, low 0.2 W power draw, and IP50 dust protection for indoor distribution cabinets, laboratory apparatus, and appliance control boards, backed by verified RoHS compliance.
Quick Specifications
| Specification Attribute | FL1P-10NJ-3 Value / Details |
|---|---|
| Product Description | Plastic led bulb indicator / panel-mount LED pilot lamp |
| Model Designation | FL1P-10NJ-3 |
| Mounting Hole Size | 10mm (approx. Ø0.394 in; series sizes include 6mm, 8mm, 10mm, 12mm, 16mm, 22mm) |
| Rated Operating Voltage | 2V / 3V / 6V / 12V / 24V / 48V / 110V / 220V / 380V DC/AC (configuration-dependent; custom voltages available) |
| LED Illumination Colors | Red (R), Green (G), Yellow (Y), Blue (B), White (W) |
| Wiring Terminal Type | 2PIN plug terminals (pre-wired lead and screw terminal options exist in the wider plastic series) |
| Head Type | High-head round plastic lens |
| Mounting Method & Accessories | Nut-locking installation; includes 1X plastic indicator light and 1X plastic mounting nut |
| Surface & Assembly Quality | Smooth finish free of burrs, oxidation, or cracks; head and base tightly fitted without rotation or tilt |
Performance Parameters
| Electrical / Mechanical Parameter | Specified Value & Test Condition |
|---|---|
| AC Supply Frequency | 50 / 60 Hz |
| Rated Operating Current | ≤ 20 mA |
| Rated Power Consumption | Approx. 0.2 W |
| Insulation Resistance | ≥ 100 MΩ (measured at 500 V DC applied between terminals and housing) |
| Dielectric Strength | 1500 V AC for 1 minute without breakdown or flashover |
| Rated Working Life | 60,000 hours (rated operational life under specified conditions, not a warranty period) |
| Ingress Protection | IP50 (dust-protected for indoor and enclosed panel installations) |
| Product Compliance | RoHS compliant (confirm CE, VDE, or CCC mark documentation for specific configurations with FILN) |
Component Materials
| Component | Material | Engineering Selection Rationale |
|---|---|---|
| Enclosure / Body | Nylon PA66 | Selected for high electrical insulation, thermal resistance, lightweight handling, and cost efficiency |
| Base | Nylon PA66 | Maintains terminal alignment and dielectric isolation around the 2PIN plug contacts |
| High-Head Lens | Nylon PA66 | Diffuses LED light evenly across the protruding round dome while resisting panel heat |
| Light Source | 5mm non-polarity LED | Delivers long operational life, low power draw, and polarity-free wiring convenience |
| Current-Limiting Element | Carbon film resistor | Regulates forward current across configured DC/AC supply voltages |
| Mounting Hardware | 1X plastic locking nut | Included with the FL1P-10NJ-3 nut-locking model to secure the threaded body behind the panel |
Environmental Performance
| Environmental Parameter | Specified Range / Test Condition |
|---|---|
| Operating & Storage Temperature | −15°C to +80°C |
| Operating Relative Humidity | ≤ 85% RH at +40°C |
| High-Temperature Endurance Test | 96 hours at 80 ± 2°C |
| Low-Temperature Endurance Test | 96 hours at −15 ± 2°C |
| Steady-State Damp Heat Test | 96 hours at 40 ± 2°C, 90% to 95% RH |
| Thermal Cycling Test | −15°C (30 min) to +80°C (30 min) for 5 cycles |
LED Specification
The internal 5mm LED emitter inside this led bulb indicator is rated under the following absolute maximum limits and electro-optical characteristics at Ta = 25°C:
| Absolute Maximum Rating | Symbol | Limit Value |
|---|---|---|
| Maximum Forward Current | IFP | 20 mA |
| Reverse Voltage | VR | 5 V |
| Power Dissipation | PD | 60 mW |
| Operating Temperature Range | TOPR | −15°C to +80°C |
| Storage Temperature Range | TSTG | −15°C to +100°C |
| Lead-Free Soldering Temperature | TSOL | Max. 260°C for up to 3 seconds |
| LED Color | Forward Voltage VF (IF = 20 mA) | Luminous Intensity Iv (IF = 20 mA) | Dominant Wavelength λd (IF = 20 mA) | Viewing Angle 2θ½ |
|---|---|---|---|---|
| Red (R) | 1.8 – 2.2 V | 1000 – 1500 mcd | 620 – 625 nm | Typical 60° |
| Green (G) | 3.0 – 3.2 V | 8000 – 10000 mcd | 520 – 525 nm | Typical 35° |
| Yellow (Y) | 2.0 – 2.2 V | 1000 – 1500 mcd | 588 – 592 nm | Typical 35° |
| Blue (B) | 3.0 – 3.2 V | 2000 – 3000 mcd | 460 – 465 nm | Typical 35° |
| White (W) | Not specified in the available product data | Not specified in the available product data | Not specified in the available product data | Not specified in the available product data |
Note: Recommended forward current IF is typically 20 mA; maximum reverse current IR is 3 µA at VR = 5 V.
Standard Test Conditions
Unless stated otherwise in the product datasheet, all electrical and optical measurements for this led bulb indicator are performed under standard atmospheric conditions: ambient temperature of 5°C to 35°C, relative humidity of 45% to 85% RH, and barometric pressure between 86 kPa and 106 kPa (860 to 1060 mbar). Luminous intensity and dominant wavelength values are calibrated against CIE standard eye response curves, with measurement tolerances of ±15% for luminous intensity and ±0.1 V for forward voltage.
Applications by Industry
Because the FL1P-10NJ-3 led bulb indicator combines a lightweight Nylon PA66 body, IP50 dust resistance, and −15°C to +80°C thermal rating, it fits enclosed panels and indoor electrical assemblies across multiple sectors:
- Industrial Automation & Power Distribution Cabinets: Installed on PLC enclosures, CNC operator consoles, and switchgear doors where IP50 dust protection and −15°C to +80°C operating temperatures are sufficient.
- Experimental & Laboratory Testing Instruments: Used on measurement benches, educational power supplies, and diagnostic consoles requiring high electrical insulation and clear status indication.
- New Energy Equipment Enclosures: Integrated into indoor inverter status boards, battery management display panels, and energy monitoring cabinets within controlled temperature ranges.
- Home Appliances & Commercial Equipment: Mounted on coffee machines, commercial kitchen units, and indoor vending systems where compact 10mm cutouts and cost-effective assembly are required.
- Automotive & Yacht Interior Dashboards: Applied inside dry vehicle cabins, custom truck switch panels, and enclosed marine helm consoles protected from water spray or washdown.
When comparing housing families, plastic indicator lights are typically selected for weight reduction, dielectric isolation, and economical high-volume panel assembly, whereas metal indicator lights are chosen for higher mechanical impact resistance or harsher exposed environments. If your application involves outdoor exposure, high-pressure washdown, or temperatures outside −15°C to +80°C, consult FILN to select an alternative sealed configuration.

LED Indicator Color Meanings and Application Guide
Choosing the appropriate lens and emitter color for a led bulb indicator helps operators interpret machine conditions quickly. Color conventions vary by equipment manufacturer, control architecture, industry sector, and national or regional standards, so always verify project-specific wiring schematics before finalizing color assignments:
| LED Color | Common Industrial Meaning | Typical Equipment Status | Typical Application | Selection & Usage Notes |
|---|---|---|---|---|
| Red (R) | Danger, stop, fault, or emergency condition | Overload trip, emergency stop active, fault alarm | Distribution panels, motor starters, alarm boxes | Reserve for urgent alerts or energized live-bus warnings depending on local standard |
| Green (G) | Normal operation, safe state, or ready | Motor running, normal cycle active, system ready | Automation consoles, lab test rigs, appliances | High luminous intensity (8000–10000 mcd) ensures clear visibility in bright rooms |
| Yellow (Y) | Caution, abnormal condition, or standby | Warm-up phase, threshold warning, standby | Heating controllers, process panels, battery racks | Signals operator attention before a critical fault occurs |
| Blue (B) | Mandatory action or operator intervention | Reset required, manual mode, auxiliary pump on | PLC interfaces, vehicle switch panels, HVAC boards | Useful when distinguishing special functions from standard run/fault lights |
| White (W) | General power presence or neutral confirmation | Main control power energized, circuit available | Power distribution cabinets, commercial equipment | Chosen where no specific safety color meaning is mandated; bi-color or tri-color options may be available where applicable—confirm with FILN |
How to Install a Plastic Indicator Light
The FL1P-10NJ-3 led bulb indicator uses a threaded barrel and plastic locking nut for clean front-of-panel assembly. Follow these sequential steps for mechanical mounting:
- Required Tools: Prepare a 10mm drill bit or panel punch, deburring tool, insulated wire stripper, and compatible 2PIN female receptacle connectors or insulated crimp terminals.
- Mounting Preparation: Disconnect all electrical power to the enclosure and verify adequate rear clearance behind the panel for the indicator barrel and 2PIN plug terminals.
- Mounting Hole Requirements: Drill or punch a clean 10mm (Ø0.394 in) circular aperture in the panel. Remove sharp burrs so the Nylon PA66 threads seat evenly.
- Product Orientation: Unthread the included plastic locking nut from the rear of the indicator body. Orient the high-head round lens toward the operator side of the panel.
- Installation Steps: Insert the threaded barrel through the 10mm cutout from the front of the panel. Thread the plastic locking nut onto the barrel from the rear side and tighten firmly by hand until the bezel sits flush against the panel face.
- Wiring Preparation: Confirm that the supply voltage (AC or DC) matches the ordered rating of the indicator before stripping or terminating conductors.
- Electrical Connection: Attach the insulated female plug connector or crimped terminal sleeves onto the 2PIN plug pins securely.
- Panel Fit and Sealing Notes: Because the FL1P-10NJ-3 is rated at IP50 for dust protection in enclosed panels, it does not include a waterproof O-ring seal and must not be exposed to liquid spray or washdown.
- Inspection After Installation: Check that the lens does not rotate or tilt, verify snug nut tension, and confirm no bare conductor strands are exposed near adjacent metallic components.
- Common Installation Mistakes: Avoid over-tightening the plastic nut with metal pliers (which can strip PA66 threads), drilling oversized cutouts above 10mm, or applying line voltage to a low-voltage DC unit.
- Safety Precautions: Always lock out and tag out power sources before servicing control panels, and keep operating temperatures within −15°C to +80°C.

How to Wire a Plastic Indicator Light
The FL1P-10NJ-3 model is built with 2PIN plug terminals, while other models in the FILN plastic indicator series are offered with pre-wired PVC leads (such as AWG22, 185mm) or screw terminals. Always disconnect power completely before wiring. Because this series integrates a 5mm non-polarity LED light source, DC installations do not require matching positive (+) and negative (−) leads to specific pins—simply connect the two supply conductors across the 2PIN terminals after verifying that your circuit voltage and AC/DC type match the ordered configuration. When wiring pre-wired lead models in the broader product line, join conductors using quick-disconnect terminals, proper soldering with heat-shrink tubing, or insulated crimp connectors so every joint remains mechanically secure and electrically isolated.
| Evaluation Dimension | 2PIN Plug Terminal Indicator (FL1P-10NJ-3) | Pre-Wired Lead Indicator (Series Option) |
|---|---|---|
| Termination Structure | Two rigid metal plug pins extending from the PA66 base | Factory-attached flexible insulated wires (e.g., AWG22, 185mm) |
| Key Advantages | Enables plug-and-play harness assembly, fast swap-out during maintenance, and neat rear panel layout | Ready for direct splicing, terminal block clamping, or routing into tight spaces without separate plug housings |
| Practical Limitations | Requires matching female receptacles or insulated spade/pin sleeves; avoid prolonged manual soldering over 260°C / 3 s | Fixed lead length requires wire bundling and external splice insulation during installation |
| Recommended Scope | Modular control panels, standardized OEM harnesses, and serviceable industrial equipment | Automotive dashboard retrofits, home appliances, and point-to-point terminal block wiring |
Industry Knowledge Center
Industrial buyers and control engineers frequently evaluate regional compliance frameworks—such as CE, VDE, UL, CCC, and RoHS—alongside IEC panel color conventions when specifying signaling devices for export machinery. While this FL1P-10NJ-3 offering is verified as RoHS compliant, procurement teams should always request configuration-specific test reports or certificates from the manufacturer before final qualification. During operation, a common troubleshooting issue on low-voltage LED pilot lights is faint glowing or phantom illumination when the control switch is off. Because LEDs draw minimal current (≤ 20 mA), small leakage currents from PLC triac outputs, solid-state relays, or induced capacitive coupling along parallel AC cables can partially excite the LED. Adding a parallel bleeder resistor across the indicator terminals drains stray leakage current and restores a completely dark off-state. Routine maintenance consists of keeping dust accumulation off the lens surface and verifying terminal tightness during scheduled cabinet inspections.
How to Choose a Plastic Indicator Light
Selecting the right led bulb indicator requires matching mechanical cutout dimensions, supply voltage, housing material, and environmental sealing to your equipment enclosure. To explore other lens profiles and termination options within the same cutout family, browse more 10MM plastic indicator lights on our product catalog.
1. Panel Cutout Sizing Guide
| Metric Cutout Size | Approximate Inch Equivalent | Typical Panel Application |
|---|---|---|
| 6mm | Ø0.236 in (approx. 0.24 in) | Ultra-compact PCB sub-panels and miniature instruments |
| 8mm | Ø0.315 in | Dense appliance control boards and compact switches |
| 10mm (This Model) | Ø0.394 in | Control boxes, laboratory instruments, distribution cabinets, automotive panels |
| 12mm | Ø0.472 in | General machinery panels and commercial equipment |
| 16mm | Ø0.630 in | Industrial operator stations matching 16mm push-button grids |
| 22mm | Ø0.866 in | Standard switchgear and heavy electrical control cabinets |
2. Housing Material Comparison (PA66 Plastic vs. Metal Families)
This SKU uses Nylon PA66 for electrical insulation, light weight, and economical panel assembly. For applications requiring metallic bodies (separate housing families), compare the material trade-offs below or click here to view metal indicator lights:
| Housing Material Family | Key Advantages | Limitations | Suitable Environment |
|---|---|---|---|
| Nylon PA66 Plastic (This SKU) | Full dielectric insulation, lightweight, corrosion-free, cost-effective | Lower impact resistance than metal; IP50 rating in this model | Enclosed indoor panels, appliances, dry instruments (−15°C to +80°C) |
| Nickel-Plated Brass (Other Family) | Strong mechanical rigidity, clean metallic finish, good machinability | Higher unit weight and cost; conductive metal bezel | General industrial machinery and commercial control panels |
| Stainless Steel (Other Family) | High impact durability, strong corrosion resistance | Highest material cost and heavier panel load | Harsh industrial, outdoor, or marine deck equipment (with sealed IP configurations) |
| Zinc Alloy (Other Family) | Economical die-cast metal strength for standard bezels | Lower corrosion resistance than stainless steel in wet environments | Indoor machinery consoles requiring metal bezels |
3. Specification-to-Decision Framework & Certification Note
For regulatory compliance, this product offering is verified as RoHS compliant; if your target market requires CE, VDE, UL, or CCC marks, list those requirements in your RFQ so FILN engineering can confirm eligible configurations and documentation. Use the decision matrix below when finalizing your order:
| Key Specification | What It Means & Why It Matters | When to Choose Another Option & What to Confirm |
|---|---|---|
| Ingress Protection (IP50) | Protects internal contacts against harmful dust in indoor cabinets | Choose a sealed IP65/IP67 series if exposed to rain, splash, or washdown; confirm panel environment |
| Voltage Rating (2V–380V AC/DC) | Internal resistor is matched to your control circuit voltage | Specify exact voltage (e.g., 12V DC, 24V AC/DC, 220V AC) before ordering; never interchange ratings |
| 2PIN Plug Terminals | Supports detachable plug-in wiring harnesses | Choose pre-wired leads or screw terminals if your assembly lacks plug housings |
| Temperature (−15°C to +80°C) | Ensures stable PA66 housing and LED performance inside panels | Request high-temperature or cold-climate models if ambient conditions exceed this range |
4. B2B Procurement RFQ Checklist
When submitting an inquiry to FILN, please specify the following details: product type, model number (FL1P-10NJ-3), mounting hole size (10mm), operating voltage, AC/DC supply type, LED color, head type (high-head round), housing material (Nylon PA66), IP protection requirement, wiring method (2PIN plug or wire lead), wire length and connector requirement (if applicable), certification requirement, order quantity, packaging preference, OEM/logo/custom marking needs, target market, application environment, and your expected delivery date.
Providing these specifications helps FILN engineering and sales teams confirm product compatibility and quotation requirements more efficiently.
| Request a Quotation | Request a Sample |
| Request Datasheet PDF | Request 3D Model / CAD |
FILN Manufacturing and Engineering Capabilities
As an indicator light manufacturer, FILN supports industrial buyers, OEMs, and electrical distributors with dedicated R&D, application engineering, and OEM/ODM customization. Our engineering team assists procurement and design departments with custom voltage matching, wire harness integration, connector termination, custom lens markings, and 3D CAD drawings so components integrate smoothly into your panel layouts. From prototype sample verification and small-batch pilot runs to full-scale mass production, every batch undergoes electrical continuity, dielectric strength, and optical inspection in our in-house testing laboratory. FILN also provides certification support to help buyers identify and verify applicable regional compliance marks for their target export markets.

Factory Direct Supply
Yueqing Yulin Electronic Co., Ltd, operating under the brand name FILN, is located in Wenzhou, Zhejiang, and was established in 2006 as an electrical switch and indicator manufacturer integrating R&D, production, and international sales. FILN-brand products are exported to more than 100 countries across North America, Europe, and Asia-Pacific. Operating a 10,000 m² manufacturing facility equipped with over 20 production lines and an independent testing laboratory, the company maintains an ISO9001 quality management system across its production of indicator lights, push-button switches, rocker switches, toggle switches, and custom miniature electrical components.
Note on compliance scope: While this specific plastic led bulb indicator offering is verified as RoHS compliant, FILN manufactures broader product lines that hold or support company-level and series-specific marks such as ISO9001, CE, VDE, RoHS, SGS, UL, TÜV, CCC, and IP65 sealed ratings—please confirm exact model certifications with our engineering team prior to ordering. Visit the FILN Official Website, purchase standard 10mm units directly on our 10mm Plastic LED Indicator Product Page, or contact sales at inquiry@cnylin.com.cn.

Open Full Plastic Indicator Category
Frequently Asked Questions
What is a FILN plastic led bulb indicator?
A FILN plastic led bulb indicator is a panel-mounted visual status pilot lamp constructed with a Nylon PA66 enclosure, base, and lens paired with an internal LED and current-limiting resistor. Model FL1P-10NJ-3 fits a 10mm cutout with a high-head round dome and 2PIN plug terminals for electrical panels and equipment.
What mounting hole size does the FL1P-10NJ-3 require?
Model FL1P-10NJ-3 requires a standard 10mm (approximately Ø0.394 in) circular panel cutout. Within the broader FILN plastic indicator light family, mounting sizes are also available in 6mm, 8mm, 12mm, 16mm, and 22mm to accommodate different panel layouts.
What voltages can this plastic led bulb indicator operate on?
Depending on the ordered configuration, this plastic indicator series supports 2V, 3V, 6V, 12V, 24V, 48V, 110V, 220V, and 380V DC/AC at 50/60 Hz, as well as custom-engineered voltage ratings. Always confirm the exact voltage and AC/DC type on your purchase order.
Is this 10mm plastic led bulb indicator waterproof?
No, this series is rated at IP50 ingress protection, which provides dust resistance suitable for indoor control cabinets and enclosed panels. It is not rated for outdoor rain exposure, liquid washdown, or submersion; contact FILN if you need a sealed IP65 or IP67 indicator model.
How is the FL1P-10NJ-3 installed onto an equipment panel?
This model uses a nut-locking installation method. Drill a clean 10mm circular hole in the panel, insert the indicator barrel from the front side, thread the included plastic locking nut onto the rear threads, and hand-tighten until the bezel rests securely against the panel.
How do I wire a 2PIN plug indicator versus a pre-wired plastic indicator light?
For the 2PIN plug FL1P-10NJ-3 model, connect compatible female plug connectors or insulated terminal sleeves onto the two rear pins after turning off power. Pre-wired models in the broader series include factory-attached PVC leads (such as AWG22, 185mm) for direct splicing or terminal block clamping.
What does the 5mm non-polarity LED mean for electrical wiring?
A 5mm non-polarity LED allows the led bulb indicator to illuminate regardless of which wire is connected to the positive or negative terminal in DC circuits. This eliminates reverse-polarity wiring errors during panel assembly while still requiring adherence to the rated supply voltage.
How do I prevent phantom illumination or faint glowing on a low-voltage LED indicator?
Faint glowing when a circuit is switched off is typically caused by small leakage currents from PLC solid-state outputs or capacitive coupling in long parallel AC cables. Connecting an appropriately sized bleeder resistor in parallel across the indicator terminals bypasses stray leakage current and eliminates phantom illumination.
What certifications apply to this plastic led bulb indicator?
This specific product offering is verified as RoHS compliant. While FILN maintains an ISO9001 quality management system and manufactures product lines with CE, VDE, UL, TÜV, or CCC marks, buyers should request configuration-specific compliance certificates from FILN before ordering.
What material is used for the housing, base, and high-head lens?
The enclosure, internal base, and high-head round lens of this indicator are molded from Nylon PA66. This engineering polymer provides strong electrical insulation (≥ 100 MΩ at 500 V DC), lightweight handling, and thermal stability between −15°C and +80°C.
What is the operating temperature range for this series?
The rated operating and storage temperature range for this plastic led bulb indicator series is −15°C to +80°C, with operating relative humidity up to 85% RH at +40°C. Avoid installing this model in environments exceeding +80°C or below −15°C.
What is the rated working life of this indicator light?
This led bulb indicator has a rated operational working life of 60,000 hours when operated within its specified voltage, current (≤ 20 mA), and −15°C to +80°C environmental limits. This figure represents expected technical service life under test conditions rather than a commercial warranty period.
What LED colors are available and what are their optical specifications?
Available LED colors are Red (620–625 nm, 1000–1500 mcd), Green (520–525 nm, 8000–10000 mcd), Yellow (588–592 nm, 1000–1500 mcd), Blue (460–465 nm, 2000–3000 mcd), and White. Detailed photometric values for the White LED option are not specified in the available product data.
When should I choose a plastic led bulb indicator instead of a metal one?
Choose a plastic led bulb indicator when your panel design prioritizes full electrical insulation, lightweight construction, corrosion resistance, and economical unit cost in enclosed indoor environments. Select a metal indicator light family when high mechanical impact resistance or heavy-duty exterior durability is required.
Can FILN customize voltage, LED color, wire leads, or OEM markings?
Yes. As a direct manufacturer, Yueqing Yulin Electronic Co., Ltd (FILN) provides OEM and ODM customization for operating voltages, LED colors, pre-wired harness lengths, connectors, and custom housing markings. Contact inquiry@cnylin.com.cn to review custom engineering requirements.
What accessories are included with the FL1P-10NJ-3 indicator?
Each FL1P-10NJ-3 package includes 1X high-head round plastic indicator light and 1X matching plastic locking nut for panel mounting. Female wire connectors or harness plugs are not included unless specified in a custom assembly order.
How can engineers request a PDF datasheet or 3D CAD model?
Procurement engineers and panel designers can request dimensional drawings, full technical datasheets, and 3D CAD files directly by emailing FILN technical support at inquiry@cnylin.com.cn or visiting the FILN Official Website.
Where can I buy this 10mm plastic led bulb indicator online?
You can order standard 10mm plastic LED indicator lamps directly through our online store at CNFILN 10mm Plastic LED Indicator Product Page, or browse additional 10mm styles on IndicatorLight.com.
What information should B2B buyers include in an RFQ?
To receive an accurate quotation, include the model number (FL1P-10NJ-3), 10mm cutout size, voltage and AC/DC type, LED color, terminal type (2PIN plug or pre-wired), required certifications, order quantity, and target delivery date when emailing inquiry@cnylin.com.cn.
Does FILN support sample testing before bulk production orders?
Yes, FILN supports sample requests for electrical testing, mechanical panel fit verification, and pilot assembly evaluation prior to volume procurement. Submit your sample specifications via inquiry@cnylin.com.cn or explore our full panel indicator catalog.