Product Category

Search

12V LED Panel Indicator Light 10mm Snap-In Plastic Signal Light FILN

Product Specifications
• Model: FL1P-10QJ-1
• Color: Red, green, yellow, blue, or white
• Shape: Round
• Material: Lightweight plastic housing
• Finish Type: Plastic finish
• Light Source Type: LED
• Rated Voltage: Configurable from 3V to 480V AC/DC
• Rated Current: Customizable
• Mounting Type: Snap-fit mounting structure
• Terminal / Wiring: Two plug-in terminals
• Protection Rating: CE, VDE, RoHS, ISO9001 Certified
• Product Size: 10 mm (0.39 inch)
• Other Key Specifications: Designed for electrical equipment, control panels, and instrument panels
• Download PDF: FILN 10mm Plastic LED Panel Indicator FL1P-10QJ-1 Datasheet
• Email: inquiry@cnylin.com.cn

About this item
• Main Advantage: The FL1P-10QJ-1 LED panel indicator provides clear, visible operating-status signals for electrical equipment, control panels, and enclosed instrument panels.
• Durability & Reliability: Features a lightweight plastic housing and snap-fit mounting structure, backed by CE, VDE, RoHS, and ISO9001 factory certifications for reliable performance.
• Installation & Compatibility: Engineered for quick installation in a 10 mm (0.39 inch) panel opening with two plug-in terminals for straightforward electrical connection.
• Applications: Perfectly suited for equipment manufacturers, panel builders, industrial control systems, automation machinery, and electronic instrument panels.
• OEM & ODM: Factory support includes sample requests, technical confirmation, customized production, voltage configurations from 3V to 480V, and multiple LED color options.

FL1P-10JQ-1-9

Product Summary

The FILN FL1P-10QJ-1 is a 10mm round plastic LED panel indicator designed to provide visible operating-status signals on electrical equipment, control panels and enclosed instrument panels. This 12V LED panel indicator configuration uses a lightweight plastic housing, a snap-fit mounting structure and two plug-in terminals for electrical connection. The product supports configurable operating voltages from 3V to 480V, subject to the ordered electrical configuration, and is available with red, green, yellow, blue or white illumination. Buyers should confirm the panel opening, voltage, AC or DC supply, LED polarity, color and installation environment before ordering.

FILN supplies plastic indicator lights for equipment manufacturers, panel builders, distributors and OEM customers. Sample requests, technical confirmation and customized production can be discussed with the FILN team.

Product identification

Model: FL1P-10QJ-1 | Mounting size: 10mm | Head: Round plastic | Connection: 2-pin plug-in terminals | Mounting: Snap-fit

View the 10mm Plastic LED Indicator Product Page

Key Takeaways

  • A 10mm round plastic LED panel indicator for equipment and control-panel status indication.
  • Model FL1P-10QJ-1 with a two-pin plug-in terminal connection.
  • Snap-fit mounting with retaining features on the housing; no separate fixing nut is specified for this configuration.
  • Configurable voltage from 3V to 480V, subject to confirmation of the exact electrical version.
  • Five LED color choices: red, green, yellow, blue and white.
  • LED polarity options include polarity-sensitive and non-polarity configurations. Confirm the selected version before wiring.
  • Plastic construction provides a lightweight and cost-conscious alternative to many metal indicator designs.
  • The series default environmental specification is IP50 and −15°C to +80°C. Confirm suitability for the actual installation environment.
  • The product information supplied for this offering states CE, VDE, RoHS and CCC marks. Request the applicable documentation for the exact configuration. ISO9001 refers to the company quality-management system.
  • Before placing a bulk order, confirm panel-hole size, panel thickness, voltage, AC/DC supply, LED color, polarity and terminal compatibility.

What Is a Plastic Indicator Light?

Definition

A plastic indicator light is a panel-mounted visual signaling component that uses an LED light source inside a plastic housing to show the operating condition of electrical equipment. A 12V LED panel indicator is commonly selected when a machine builder needs a compact status light for a 12V control circuit. The actual voltage must match the ordered indicator configuration and the electrical supply.

Function and Purpose

The indicator converts an electrical signal into a visible light. Depending on the equipment control logic, the illuminated color can represent power availability, normal operation, standby, warning or another assigned machine status. The meaning of each color should be defined by the equipment manufacturer and shown in the machine documentation.

Basic Structure

A typical plastic LED panel indicator consists of a front lens or head, a plastic housing, an LED light source, a current-limiting component and electrical terminals or leads. The FL1P-10QJ-1 uses a round plastic head and two plug-in terminals. Its snap-fit housing is designed to engage with a compatible panel opening.

Plastic and Metal Indicator Categories

Panel indicators are commonly available in plastic and metal constructions. Plastic versions are often chosen for lightweight equipment, electrical appliances and cost-sensitive panel assemblies. Metal indicators may be preferred when the application requires a different appearance or a more mechanically robust front construction. The correct choice depends on the environment, mounting design and product specification.

Common Plastic Indicator Sizes and Connections

Plastic indicator families are commonly offered in nominal mounting sizes such as 6mm, 8mm, 10mm, 12mm, 16mm and 22mm. Depending on the model, connection options across the product family can include pin terminals, pre-wired leads and screw terminals. These are family-level options and should not be interpreted as connection options included in every individual model.

Plastic indicator designs generally focus on practical mounting, terminal configuration, voltage selection and LED color. Metal indicator families may offer different front profiles, including flat, raised or recessed heads. Select the physical design according to the panel layout and the required visual appearance.

FILN plastic LED panel indicator light with round front lens and plastic housing

Request a Sample Buy This Indicator
Request a Quotation Request Datasheet / CAD

Browse Plastic and Panel Indicator Lights

Explore additional plastic indicator sizes, mounting styles and panel signal-light options.

Browse Plastic Indicator Category

Product Overview

The FL1P-10QJ-1 is a round 10mm plastic panel indicator with a two-pin plug-in connection. Its front section is positioned through a compatible panel opening, while the retaining features on the housing engage behind the panel to hold the indicator in place. The LED illuminates when the correctly configured electrical supply is applied.

The product is intended for applications where a compact visual signal is required without the appearance or construction of a metal indicator. The plastic construction supports lightweight panel assemblies. The series material specification uses Nylon PA66 for the enclosure, base and lens. Confirm the material and any requested variation against the drawing for the exact order.

How the Indicator Works

An LED emits light when current flows through its semiconductor junction. A current-limiting resistor is used in the indicator circuit to support the intended electrical operating condition. The correct voltage version must be selected for the equipment supply. A polarity-sensitive LED must be connected with the correct positive and negative orientation; a non-polarity version can be connected without observing LED polarity, while still respecting the rated supply and wiring instructions.

Mounting Design

This model uses a snap-fit mounting arrangement. The panel opening and panel thickness must be compatible with the retaining features of the housing. The product is inserted from the front, and the retaining ears engage behind the panel. Do not assume that a different 10mm indicator with a threaded body or fixing nut uses the same installation method.

Product-Level Certification Notes

The supplied product information lists CE, VDE, RoHS and CCC marks for this offering. Buyers should request the relevant declarations or certificates and confirm that they cover the exact model, voltage and configuration being purchased. ISO9001 is a company quality-management system certification and is not an individual indicator-light product certificate.

Quick Specifications

The following table summarizes the supplied configuration of the FL1P-10QJ-1 10mm plastic indicator. Electrical and certification details should be confirmed against the final order configuration before production.

Attribute Specification
Product model FL1P-10QJ-1
Product type Round plastic LED panel indicator
Mounting size 10mm (approximately Ø0.394 in)
Head shape Round plastic head
Connection 2-pin plug-in terminals
Mounting method Snap-fit installation with retaining features
Operating voltage 3–480V, configurable; confirm exact voltage and AC/DC version
LED colors Red, Green, Yellow, Blue, White
LED polarity Polarity-sensitive or non-polarity option; confirm when ordering
Housing material Nylon PA66 series specification; verify exact configuration
Ingress protection IP50 series specification; not a washdown or immersion rating
Operating temperature −15°C to +80°C series specification
Product marks stated for this offering CE, VDE, RoHS and CCC; request documents for the exact configuration
Company quality system ISO9001; company-level system certification
Package quantity 1 × plastic indicator

The 10mm size is the nominal mounting size. Confirm the actual panel-hole tolerance, panel thickness and retaining dimensions with the product drawing before production tooling or installation.

Performance Parameters

The electrical performance of a 12V LED panel indicator depends on the selected voltage and circuit configuration. The following series values are reference specifications; the exact ordered version must be confirmed with FILN before connecting the indicator to a machine supply.

Parameter Series Reference Notes
Rated operating voltage 3–480V, as supplied for this product offering Confirm exact voltage and AC/DC type; not every version is necessarily a standard stock item.
Rated frequency 50/60Hz For applicable AC configurations.
Rated operating current ≤ 20mA Confirm the current for the selected voltage version.
Rated power Approximately 0.2W Reference value; verify against the ordered circuit configuration.
Insulation resistance ≥ 100MΩ 500V DC applied between lead wires and housing.
Dielectric strength 1500V AC Series test reference; confirm the applicable test procedure for the exact product.
Rated operating life 60,000 hours Rated operating-life reference under specified conditions; not a warranty period.
Ingress protection IP50 Not suitable to describe as waterproof, washdown or immersion protected.

Do not connect an indicator based only on its appearance or nominal panel size. Verify the rated voltage, AC/DC supply, wiring diagram and terminal arrangement for the exact order code.

Component Materials

Material selection affects insulation, mechanical fit, heat resistance and the overall construction of a plastic LED panel indicator. The following material information follows the FILN plastic indicator series reference and should be checked against the drawing for the specific snap-fit model.

Component Material / Construction Purpose
Enclosure Nylon PA66 Plastic housing structure and electrical insulation.
Base Nylon PA66 Supports the internal components and terminal assembly.
Lens Nylon PA66 series reference Front light-transmitting component; confirm the exact material in the product drawing.
Light source LED; 5mm non-polarity LED is a series reference Produces the visual signal. Polarity-sensitive and non-polarity options should be confirmed for this order.
Current-limiting component Carbon film resistor Limits current in the indicator circuit.
Terminals 2-pin plug-in connection Provides electrical connection to the equipment wiring.

Why Nylon PA66 Is Used

Nylon PA66 is used in this plastic indicator series because it provides electrical insulation, a relatively light construction and heat resistance appropriate to the specified operating conditions. It is also suitable for compact molded components and repeatable assembly. No unverified flame-retardant grade, such as a specific UL94 classification, is claimed here.

Mounting Hardware

The supplied FL1P-10QJ-1 configuration uses snap-fit retaining features. A separate mounting nut, O-ring or lock washer is not specified for this snap-fit arrangement. Do not apply hardware information from threaded or other plastic indicator models to this product.

Environmental Performance

The FILN plastic indicator series reference specifies IP50 ingress protection and an operating and storage temperature range of −15°C to +80°C. These limits should guide application selection. This product should not be described as suitable for water jets, immersion, outdoor weather exposure or aggressive chemical cleaning unless a separately verified configuration is selected.

Environmental Parameter Series Reference
Ingress protection IP50
Operating temperature −15°C to +80°C
Storage temperature −15°C to +80°C for the series reference
Relative humidity ≤85% at +40°C
High-temperature test 96 hours at 80±2°C
Low-temperature test 96 hours at −15±2°C
Constant temperature and humidity test 96 hours at 40±2°C and 90%–95% RH
Temperature cycling test −15°C for 30 minutes and 80°C for 30 minutes, 5 cycles

These are series reference conditions, not a claim that the indicator is waterproof or suitable for every environment. Confirm the complete product specification and installation conditions before use.

LED Specification

The 10mm plastic indicator is available with red, green, yellow, blue or white LED illumination. LED electrical and optical values depend on the selected color and configuration. The values below are series reference data at Ta = 25°C and should be checked against the exact LED fitted to the ordered version.

LED Absolute Maximum Ratings

Parameter Symbol Series Reference
Maximum forward current IFP 20mA
Reverse voltage VR 5V
Power dissipation PD 60mW
Operating temperature TOPR −15°C to +80°C
Storage temperature TSTG −15°C to +100°C
Lead-free soldering TSOL Up to 260°C for no more than 3 seconds

Optical and Electrical Characteristics

Characteristic Red Green Yellow Blue White
Forward voltage VF at IF=20mA 1.8–2.2V 3.0–3.2V 2.0–2.2V 3.0–3.2V Not specified in the available product data
Luminous intensity at IF=20mA 1000–1500mcd 8000–10000mcd 1000–1500mcd 2000–3000mcd Not specified in the available product data
Viewing angle 2θ½ Typical 60° Typical 35° Typical 35° Typical 35° Not specified in the available product data
Dominant wavelength λd 620–625nm 520–525nm 588–592nm 460–465nm Not specified in the available product data
Reverse current at VR=5V Maximum 3µA, series reference

White is listed as an available LED color, but its forward voltage, luminous intensity, viewing angle and dominant wavelength are not specified in the available product data. Confirm the white LED configuration with FILN before engineering approval.

Standard Test Conditions

Standard test conditions provide a consistent reference for evaluating the plastic indicator series. Unless another condition is stated, the following atmospheric conditions and measurement references apply to the supplied series data.

Test Condition Reference
Ambient temperature 5°C to 35°C
Relative humidity 45% to 85%
Atmospheric pressure 86 to 106kPa (860 to 1060mbar)
Luminous intensity and dominant wavelength Calibrated according to the CIE human-eye response curve
Luminous intensity tolerance ±15%
Voltage tolerance ±0.1V

Measurement values may vary with LED color, voltage configuration and test setup. For a regulated project, request the latest product specification and applicable inspection records for the exact order configuration.

Applications by Industry

A 10mm plastic LED panel indicator can be used wherever a compact visual status signal is required and the panel design, voltage and environmental conditions match the product specification. The FL1P-10QJ-1 is intended for compatible equipment panels and enclosed applications within its specified IP50 and temperature limits.

Large Electrical Equipment and Industrial Control Panels

The indicator can show power status, operating state or warning signals on electrical equipment, control cabinets and machine panels. A 12V LED panel indicator configuration may be selected for equipment designed around a compatible 12V control circuit. Confirm the supply type and rated voltage before installation.

Laboratory and Testing Equipment

Laboratory instruments and testing equipment often use compact front-panel lights to communicate power, standby and test status. The plastic housing is suitable for designs that prioritize a lightweight panel component. The complete equipment enclosure and cleaning method must remain compatible with IP50 and the specified temperature range.

Distribution Cabinets and New Energy Equipment

Distribution cabinets, battery-related equipment and new energy control assemblies may use panel indicators to display circuit or operating conditions. Select the voltage version according to the actual control circuit. The indicator itself should be installed in a protected panel location that does not expose it to water jets or immersion.

Yachts and Marine Equipment Panels

A plastic panel indicator may be considered for protected indoor or enclosed equipment panels on yachts and marine systems when the installation environment is within the product rating. IP50 does not mean marine waterproofing. Do not install this configuration where it is directly exposed to seawater, spray, washdown or persistent moisture without confirming a separately suitable product.

Household Appliances and Consumer Equipment

Appliance manufacturers can use compact plastic indicators to show power, heating, operating or standby conditions. The selected voltage and LED color should match the appliance circuit and its user-interface design.

Automotive Modification and Vehicle Equipment

The indicator may be considered for protected interior equipment panels and controlled cabin applications. Confirm vibration, temperature, electrical transients and installation requirements for the vehicle. This product information does not establish suitability for an engine compartment, exterior bodywork or other harsh automotive environments.

Application Suitability

All application examples are subject to the product’s IP50 rating and −15°C to +80°C series temperature range. For outdoor exposure, washdown, immersion, high-impact locations or chemical cleaning, ask FILN to review another suitable configuration rather than assuming this model meets those conditions.

Plastic LED panel indicator examples installed in electrical equipment and control panels

LED Indicator Color Meanings and Application Guide

LED colors help operators distinguish equipment states at a glance. Red, green, yellow, blue and white are common panel-indicator choices, but their meanings depend on the machine builder, control system, industry, country and application. A color should never be assigned a universal meaning without a relevant standard or equipment-specific definition.

Color Common Meaning Typical Status Typical Application Selection Note
Red Often associated with a fault, stop or urgent warning Alarm, abnormal condition or stop status Machine control panels and equipment alarms Define the exact alarm meaning in the machine documentation.
Green Often associated with normal or ready status Running, ready or normal operation Control cabinets and electrical equipment Confirm whether green means powered, ready or running.
Yellow / Amber Often associated with caution or an intermediate condition Warning, standby or attention required Industrial machines and testing equipment Specify the event that triggers the warning.
Blue Often assigned to a special or operator-defined status Manual action, special mode or maintenance status Equipment interfaces and control stations Explain the meaning in the operating instructions.
White Often used for general or neutral indication Power availability or general status Appliances, cabinets and instrument panels Check visibility against the panel background and ambient light.

Choosing a Color for a 12V LED Panel Indicator

When selecting a 12V LED panel indicator, consider the existing color convention used by the equipment, the visibility of the illuminated lens, ambient lighting and the operator’s expected response. Color alone should not replace written labels, alarm descriptions or other safety communication methods.

Single-Color and Multi-Color Options

Red, green, yellow, blue and white are listed as color options for this product offering. Dual-color or tri-color configurations are available where applicable; confirm availability and the required circuit arrangement with FILN. Do not assume that a multi-color function is included in the standard FL1P-10QJ-1 configuration.

How to Install a Plastic Indicator Light

The FL1P-10QJ-1 uses a 10mm snap-fit mounting design. Installation requires a compatible panel opening and sufficient clearance behind the panel for the two-pin terminals and retaining features. Confirm the drawing and panel thickness before cutting or machining the panel.

Plastic indicator light snap-fit installation reference for a panel opening

1. Required Tools

Prepare the correct panel-cutting tool, measuring equipment, a suitable wiring tool and the product drawing. Use tools appropriate for the panel material and follow the equipment manufacturer’s safety procedures.

2. Mounting Preparation

Disconnect the equipment from its power source. Check the panel location, rear clearance, terminal access and the orientation of the indicator before installation.

3. Mounting Hole Requirements

The nominal mounting size is 10mm, approximately Ø0.394in. The final hole diameter and tolerance must follow the product drawing. Do not use the nominal size alone as a substitute for the drawing dimensions.

4. Product Orientation

Identify the front head, housing retaining features and two-pin terminals. Ensure that the indicator is aligned with the intended panel position and that the terminals will not be obstructed after installation.

5. Snap-Fit Installation Steps

  1. Prepare the corresponding circular panel opening according to the approved drawing.
  2. Remove burrs and debris from the opening so that the housing can seat correctly.
  3. Insert the indicator from the front side of the panel.
  4. Apply even pressure until the retaining features on the housing engage behind the panel.
  5. Check that the front head is seated evenly and that the indicator does not tilt or loosen.
  6. Confirm that the two-pin terminals remain accessible for wiring.

6. Wiring Preparation

Identify the selected voltage, AC/DC supply, terminal assignment and LED polarity option. Prepare compatible mating connectors or wiring components according to the terminal drawing.

7. Electrical Connection

Connect the two-pin terminals according to the wiring diagram for the selected version. For a polarity-sensitive LED, observe the positive and negative terminals. A non-polarity LED option does not require LED polarity orientation, but the rated voltage and circuit requirements must still be followed.

8. Panel Fit and Sealing Notes

The snap-fit retaining features must engage correctly with the panel. The series reference is IP50; the installation must not be treated as a waterproof seal. Do not expose the indicator to water jets, immersion or washdown conditions on the assumption that the snap-fit mounting provides water protection.

9. Inspection After Installation

Check the indicator’s seating, retention, terminal connection and light output. Test the unit using the correct rated supply and verify that the selected color and operating state match the equipment design.

10. Common Installation Mistakes

  • Using a hole diameter that does not match the product drawing.
  • Installing the indicator in a panel that is too thick or too thin for the retaining features.
  • Forcing the housing into an opening with burrs or an incorrect profile.
  • Applying the wrong voltage or reversing a polarity-sensitive LED connection.
  • Assuming IP50 provides waterproof or washdown protection.

11. Safety Precautions

Always isolate power before installation or wiring. Electrical work should be performed by qualified personnel in accordance with applicable local requirements. Confirm the product rating and equipment circuit before energizing the indicator.

How to Wire a Plastic Indicator Light

The FL1P-10QJ-1 is supplied with two plug-in terminals. Its wiring method is different from a pre-wired indicator with factory-attached leads. Always confirm the terminal assignment, voltage and polarity option for the exact version before connecting the 12V LED panel indicator to the equipment circuit.

Two-Pin Plug-In Terminal Wiring

  1. Disconnect the equipment from its power supply.
  2. Check the rated voltage and whether the selected indicator is for AC or DC operation.
  3. Identify the two terminals and the mating connector or wiring method specified for the product.
  4. For a polarity-sensitive LED version, connect positive and negative according to the wiring diagram.
  5. For a non-polarity LED version, LED polarity orientation is not required; the supply rating must still match.
  6. Secure the connection and ensure that exposed conductors cannot contact adjacent terminals or conductive surfaces.
  7. Restore power only after checking the connection and confirming the correct electrical configuration.

Pin-Type Versus Pre-Wired Indicators

Comparison 2-Pin Plug-In Indicator Pre-Wired Indicator
Connection Two plug-in terminals Factory-attached wire leads
Installation work Requires compatible mating connection or terminal wiring Requires routing and joining the supplied leads
Main advantage Compact terminal connection and convenient component replacement where the mating interface is standardized Wiring length and routing can be planned around the equipment assembly
Potential limitation Requires a compatible mating connector or terminal arrangement Lead routing and connection points must be managed in the equipment
Typical use Panels using a defined plug-in terminal interface Equipment where direct wire routing is preferred

The FL1P-10QJ-1 configuration described on this page is the two-pin plug-in version. Pre-wired and screw-terminal designs are product-family alternatives and should be ordered as their corresponding models, not assumed to be included with this SKU.

LED Polarity Selection

A polarity-sensitive LED requires the correct positive and negative connection. A non-polarity LED version can simplify DC wiring because the LED does not require a specific polarity orientation. This does not remove the need to select the correct rated voltage or follow the equipment wiring diagram. Confirm which LED version is supplied before production or installation.

Industry Knowledge Center

Why Panel Indicators Matter

A panel indicator gives operators a direct visual reference without requiring them to open the equipment enclosure or read a diagnostic screen. When the color and operating meaning are defined consistently, indicators can make routine operation and fault recognition easier.

Voltage Selection

The indicator’s rated voltage must match the circuit where it will be installed. A 12V LED panel indicator is appropriate only when the selected 12V version matches the equipment’s supply type and operating conditions. For other circuit voltages, specify the exact voltage and AC/DC requirement when requesting a quotation. Do not infer the internal circuit from the front appearance.

IP Rating and Installation Environment

IP50 is the series reference for this plastic indicator. It should not be described as a waterproof rating. Buyers should consider dust, moisture, condensation, cleaning procedures, vibration and ambient temperature when deciding whether the product is appropriate. For washdown, immersion or outdoor exposure, request a separately verified product configuration.

Plastic Versus Metal Construction

Plastic indicators are often selected for lower weight, electrical insulation and cost-sensitive equipment assemblies. Metal indicators may be preferred for a different front-panel appearance or where the design requires a more mechanically robust front structure. This is a qualitative comparison; actual performance depends on the specific product, material, mounting design and environmental rating.

Standards and Certification Requests

Industrial buyers may request product declarations, material information, electrical test records or market-specific compliance documents. The product information supplied for this offering lists CE, VDE, RoHS and CCC marks. Ask FILN for the documents applicable to the exact model and voltage configuration. ISO9001 describes the company’s quality-management system and should not be treated as a product certificate.

Troubleshooting: Phantom Illumination or Faint Glow

A low-voltage LED indicator may glow faintly when it is nominally switched off if a small leakage current or induced voltage remains in the circuit. Possible causes include electronic switching devices, long parallel cable runs, capacitive coupling or leakage through connected equipment. Check the circuit with suitable measuring equipment and review the switching arrangement. A qualified electrician should determine whether a correctly rated circuit solution is required; do not add components without checking the system design.

Maintenance and Inspection

Inspect the panel fit, lens condition, terminal connections and visible illumination during scheduled equipment maintenance. Replace an indicator if its housing is damaged, its retention is loose or its light output is no longer suitable for the intended status indication. Always isolate the power supply before inspection involving electrical connections.

How to Choose a Plastic Indicator Light

1. How to Choose

Start with the panel opening, supply voltage, AC/DC requirement and connection type. Then select the LED color, polarity option and environmental rating. For the FL1P-10QJ-1, the main configuration points are a nominal 10mm mounting size, round plastic head, two-pin plug-in terminals and snap-fit mounting.

2. Buying Considerations

  • Panel opening: confirm the drawing dimension and tolerance.
  • Panel thickness: check engagement of the snap-fit retaining features.
  • Voltage: specify the exact voltage rather than only stating a broad range.
  • Supply type: state AC or DC and frequency where applicable.
  • LED color: select red, green, yellow, blue or white.
  • Polarity: specify polarity-sensitive or non-polarity LED.
  • Connection: confirm the two-pin terminal and mating connection arrangement.
  • Environment: check IP50, temperature, humidity and exposure conditions.
  • Documentation: request the certificates and drawings relevant to the exact configuration.

3. Mounting Size Reference

Nominal Mounting Size Approximate Inch Equivalent Typical Panel Use
6mm Ø0.236in (about 0.24in) Compact instrument panels
8mm Ø0.315in Small equipment panels
10mm Ø0.394in Compact control and appliance panels
12mm Ø0.472in General equipment panels
16mm Ø0.630in Larger control interfaces
22mm Ø0.866in Industrial control panels

Inch values are conversion references only. Always use the product drawing to determine the final hole diameter and tolerance.

4. Certification Guide

The supplied information for this offering states CE, VDE, RoHS and CCC marks. Request the relevant documents and confirm their scope for the exact product configuration and destination market. ISO9001 is a company quality-management system certification, not an individual indicator-light certification. Do not assume that every company-level or product-family mark applies to every SKU.

5. Material Selection Guide

The FL1P-10QJ-1 belongs to the plastic indicator family and follows the Nylon PA66 series material reference. Plastic is often selected for electrical insulation, lower component weight and cost-sensitive assembly. Metal housing families may be considered when a different appearance or mechanical construction is required.

Housing Family Potential Advantages Selection Considerations
Plastic PA66 Lightweight, electrically insulating and suitable for molded snap-fit designs where specified Check the material, temperature and IP rating of the exact model.
Nickel-plated brass Metal construction and a plated front appearance A separate metal product family; confirm corrosion and mounting requirements.
Stainless steel Metal construction for applications requiring a stainless front material A separate product family; confirm grade, environment and product rating.
Zinc alloy Alternative metal housing and surface-finish options A separate product family; confirm finish and environmental suitability.

The metal materials in this table are category-level comparison examples. They are not materials specified for the FL1P-10QJ-1 plastic indicator.

6. Application Matching Guide

Match the indicator to the equipment’s panel design, electrical circuit and environmental conditions. The series reference is IP50 with an operating temperature range of −15°C to +80°C. For outdoor, washdown, immersion, high-impact or chemical-exposure applications, request an alternative configuration with verified suitability.

7. Specification-to-Decision Framework

Specification What It Means What to Confirm
10mm mounting size Nominal panel opening category Actual hole tolerance and panel thickness
3–480V configurable range Different electrical versions may be configured Exact rated voltage, AC/DC and frequency
2-pin plug-in Two electrical terminals Mating terminal and wiring compatibility
LED color Visual status indication Color, brightness and equipment color convention
LED polarity Determines whether positive/negative orientation is required Polarity-sensitive or non-polarity version
IP50 Series ingress-protection reference Whether the actual environment requires a higher rating
PA66 construction Plastic housing material reference Material documentation and any special requirements

RFQ Checklist for B2B Buyers

Providing these specifications helps FILN engineering and sales teams confirm product compatibility and quotation requirements more efficiently.

  • Product type and model number
  • Mounting-hole size and tolerance
  • Panel thickness and available rear clearance
  • Rated voltage and AC/DC supply
  • LED color and polarity requirement
  • Head style and housing material
  • Ingress-protection requirement and application environment
  • Wiring method, terminal type and connector requirement
  • Wire length, if a pre-wired alternative is requested
  • Certification and documentation requirements
  • Quantity, packaging and OEM requirements
  • Logo, custom marking and target market
  • Expected delivery date requested by the buyer
Request Technical Details Request Bulk Quotation

FILN Manufacturing and Engineering Capabilities

FILN is an electronic components manufacturer focused on the development and production of indicator lights, switches and related electrical components. For buyers sourcing a 12V LED panel indicator or a customized plastic indicator, manufacturer communication can help clarify electrical configuration, mounting compatibility, documentation and production requirements.

Product Development and Engineering Support

FILN works with customers on product selection, voltage configuration, LED color, terminal arrangements and application requirements. Buyers can provide drawings or equipment-panel details so that the engineering and sales teams can review the proposed fit and electrical configuration.

OEM and ODM Cooperation

OEM and ODM discussions can cover product configuration, appearance requirements, custom marking, packaging and other project-specific details. The available scope depends on the product design and order requirements and should be confirmed before a purchase commitment.

Production, Assembly and Quality Control

FILN’s manufacturing work covers electronic components including indicator lights, push-button switches, rocker switches and toggle switches. Product inspection and quality-control requirements should be confirmed according to the selected product, customer specification and applicable documentation.

Samples and Production Planning

Buyers can discuss sample evaluation, small-batch requirements and mass-production planning with FILN. Before requesting a sample or quotation, provide the model, voltage, LED color, terminal arrangement, mounting details and target quantity to help the team identify the correct configuration.

Certification and Documentation Support

FILN can discuss documentation and certification requirements for a target market. A request for certification support does not mean that every FILN product has every certification. Buyers should request the specific documents applicable to the exact model and configuration.

FILN electronic components manufacturer and product development overview

Factory Direct Supply

Yueqing Yulin Electronic Co., Ltd. operates under the FILN brand and was established in 2011. The company is a National High-Tech Enterprise focused on the research, development and manufacturing of waterproof switches, metal push buttons, indicator lights and related electronic components. FILN products are supplied to customers in overseas markets.

The company operates its own factory building and has more than 180 employees and over 50 patents, according to the company information supplied for this page. FILN participates in overseas exhibitions and works with international customers on product sourcing and customized electronic-component requirements.

Product Range

FILN’s product range includes plastic and metal indicator lights, push-button switches, rocker switches, toggle switches and related customized electrical components. Buyers sourcing a 12V LED panel indicator can also discuss other panel indicator sizes and connection types when planning a broader equipment project.

B2B Purchasing Support

For distributor, OEM and equipment-manufacturer inquiries, provide the required model, voltage, color, terminal type, panel opening, quantity and destination market. FILN can review the requested configuration and discuss sample evaluation, technical documentation and production requirements.

Company-Level and Product-Level Certifications

ISO9001 refers to the company’s quality-management system. Product marks stated for this offering include CE, VDE, RoHS and CCC, subject to verification of the applicable documentation for the exact model and configuration. Company-level qualifications and certificates for other product families must not be interpreted as automatic certification of this individual plastic indicator.

FILN electronic components production workshop and manufacturing environment

Explore FILN Plastic Indicator Products

Browse the wider plastic panel indicator range or contact FILN about a different mounting size and configuration.

View All Plastic Indicators

Visit FILN Official Website | Contact FILN Sales Team

Frequently Asked Questions

What is the FL1P-10QJ-1 plastic LED panel indicator?

The FL1P-10QJ-1 is a 10mm round plastic LED panel indicator with two plug-in terminals and a snap-fit mounting structure. It is designed to provide a visible operating-status signal on compatible electrical equipment and control panels. Buyers should confirm the required voltage, AC/DC supply, LED color, polarity option and panel dimensions before ordering.

What does the 10mm mounting size mean?

The 10mm designation refers to the nominal mounting-size category. Its approximate inch equivalent is Ø0.394in. The actual panel-hole diameter and tolerance must follow the product drawing. Panel thickness is also important because the housing retaining features must engage correctly behind the panel. Do not machine a production panel using only the nominal size.

What voltage can this 12V LED panel indicator use?

The supplied product information states a configurable voltage range from 3V to 480V. A 12V version can be specified when it matches the equipment circuit. The exact rated voltage, AC or DC supply and frequency must be confirmed for each order. Do not assume that every voltage within the stated range is a standard stock configuration.

Is the FL1P-10QJ-1 waterproof?

The FILN plastic indicator series reference is IP50. IP50 should not be described as waterproof, suitable for immersion or suitable for water-jet cleaning. The product should be used only where its ingress-protection rating and environmental limits are sufficient. For outdoor, marine spray, washdown or wet-area applications, ask FILN to review a different verified configuration.

How do I install this 10mm snap-fit indicator?

Prepare a circular panel opening according to the product drawing, insert the indicator from the front and allow the retaining features on the housing to engage behind the panel. Check that the front head is seated evenly and that the terminals remain accessible. The actual hole tolerance and compatible panel thickness must be confirmed before installation.

How do I connect the two-pin terminals?

The FL1P-10QJ-1 uses two plug-in terminals. Identify the terminal assignment and compatible mating connection from the product drawing. Disconnect power before wiring. For a polarity-sensitive LED, follow the positive and negative markings. For a non-polarity version, LED polarity orientation is not required, but the rated supply and circuit instructions must still be followed.

What is the difference between a pin-type and a pre-wired indicator?

A pin-type indicator has terminals that connect through a compatible plug or terminal arrangement. A pre-wired indicator has factory-attached leads that can be routed and joined within the equipment. The FL1P-10QJ-1 configuration on this page is the two-pin plug-in version. Pre-wired products are separate family options and should be specified as the corresponding model.

What does a non-polarity LED mean?

A non-polarity LED version can operate without requiring the installer to identify a positive and negative LED orientation. This can simplify some DC wiring arrangements. It does not mean that any voltage can be applied. The indicator must still match the rated voltage, AC/DC supply and circuit requirements. Confirm whether the ordered product is polarity-sensitive or non-polarity.

Why does a low-voltage LED indicator sometimes glow faintly when switched off?

A faint glow can occur when small leakage currents or induced voltages remain in a circuit after switching. Electronic switching devices, long parallel cable runs and capacitive coupling can contribute. A qualified electrician should check the circuit and switching arrangement using suitable test equipment. Do not add a resistor or other component without verifying the electrical design and safety requirements.

Which LED colors are available?

The supplied product information lists red, green, yellow, blue and white LED colors. The color should be selected according to the equipment’s status-indication logic and user-interface design. Color conventions can vary between manufacturers and industries, so the intended meaning should be documented by the equipment designer. Confirm the exact LED color before placing a production order.

Can I order a 12V red or green LED panel indicator?

The product offering lists configurable voltage and five LED color choices, including red and green. A 12V red or green version can be requested, subject to confirmation of the electrical configuration and availability. Include the required voltage, AC/DC supply, LED color, polarity option and quantity in your inquiry so FILN can confirm the requested combination.

What material is used for the plastic indicator housing?

The FILN plastic indicator series reference specifies Nylon PA66 for the enclosure and base, with Nylon PA66 also listed for the lens in the supplied material package. PA66 is selected for electrical insulation, a lightweight construction and heat resistance within the stated product limits. Confirm the material specification for the exact model and drawing before approving a project.

What is the operating temperature range?

The FILN plastic indicator series reference specifies an operating temperature range of −15°C to +80°C. The actual equipment environment should remain within the product limits, including temperature around the panel and heat generated by nearby components. If the application operates outside this range, request an alternative product configuration and supporting technical information.

What certifications apply to this product?

The supplied product information for this offering states CE, VDE, RoHS and CCC marks. Buyers should request the applicable declarations or certificates and verify that they cover the exact model and electrical configuration. ISO9001 refers to the company’s quality-management system and is not an individual product certificate. Do not assume that all company-level qualifications apply to this SKU.

Can FILN customize voltage, color or other product details?

The supplied product information identifies configurable voltage and red, green, yellow, blue and white LED choices. Buyers can discuss project requirements such as LED polarity, terminal arrangement, product marking and packaging with FILN. The available customization scope depends on the model and production requirements. Provide a drawing or technical specification when requesting a customized configuration.

When should I choose a plastic indicator instead of a metal indicator?

A plastic indicator is often considered when a lightweight, electrically insulating and cost-conscious panel component is required. A metal indicator may be more appropriate when the equipment design calls for a metal front appearance or a different mechanical construction. Compare the exact mounting design, material, ingress protection and temperature rating rather than choosing by material name alone.

What information should I include when requesting a quotation?

Include the model, mounting-hole size, panel thickness, rated voltage, AC/DC supply, LED color, polarity option, terminal type, environmental conditions, certification requirements and target quantity. Also provide the application, destination market and any drawing or mating-connector details. Complete information helps FILN review product compatibility and quotation requirements more efficiently.

Can this indicator be used in a yacht or marine control panel?

It may be considered for a protected indoor or enclosed equipment panel if the installation conditions meet the product specification. The series reference is IP50, which does not provide a waterproof or seawater-spray rating. Do not use this configuration in exposed wet locations, washdown areas or immersion conditions without selecting a separately verified product suitable for that environment.

Can I use this indicator in a distribution cabinet or new energy device?

The indicator may be suitable for an enclosed distribution cabinet or new energy equipment panel when the circuit voltage, mounting dimensions, IP50 rating and temperature limits match the application. Check the electrical supply, internal cabinet temperature, wiring clearance and environmental exposure. For outdoor or high-moisture installations, request a different verified configuration.

What is included in the package?

The supplied package information lists one plastic indicator. A separate mating connector, wiring harness, mounting nut or additional accessories are not specified as included items for this configuration. If your project requires a particular connector or accessory, state that requirement in the inquiry and confirm the final package contents before ordering.

Can I request a datasheet or 3D drawing?

Yes. Buyers can contact FILN to request available technical documentation, product drawings or CAD information for review. Include the FL1P-10QJ-1 model number and specify whether you need the mounting dimensions, terminal details, electrical specification or a 3D model. Confirm that the document matches the exact voltage and product configuration being purchased.

Inquiry Now